Colocation

The details of data center design really matter when you select a colocation provider. Uncertified infrastructure puts your business at risk whenever municipal services fail and during maintenance and upgrade activities. Why take the risk on a vendor with uncertified infrastructure?

Key Benefits of RPS Colocation

  • FedRAMP Authorized
  • FISMA Compliant
  • Uptime Institute Tier III Construction Certified site
  • Private 17 -acre campus with high security
  • 2N electrical and mechanical design
  • Up to 10 megawatt reserve power generation
  • Seven-day fuel on site supply for entire facility
  • Concurrently maintainable facilities
  • Carrier-neutral, national network

Facilities & Security

  • Certified by Uptime Institute at Tier III
  • Certified to meet GSA blast resistance standards
  • 24 x 7 customer access with on-site security
  • Dual factor access authentication
  • Ballistic mantraps and 24 x 7 video surveillance monitoring
  • FM200 and pre-action dry pipe systems
  • 24 x 7 secure loading docks and staging facilities
  • 24 x 7 kitchen, conference room and office space available
  • Private, built to suit options
  • 47U locking cabinets
  • Raised floor

Remote Support Services

  • Equipment Handling and Maintenance
  • Coordinate with client regarding power and network requirement for equipment
  • Provision appropriate power and cabling for new installs
  • Track incoming and outgoing shipments of equipment
  • Receive, unpack and rack equipment
  • Dispose of packing materials
  • Relay equipment status
  • Install power to equipment
  • Install cabling within racks per client provided instructions and diagrams
  • Move or secure cables per client provided instructions and diagrams
  • Inventory equipment as requested and report results to client
  • Label equipment and cable connections per client provided instructions and diagrams
  • De-install, pack and ship equipment as directed by client
  • Install asset tags per client direction, when necessary

Power & Cooling

  • MEP Infrastructure certified by Uptime Institute at Tier III
  • Uptime Institute AOS Certified operations staff
  • Diverse feeds from utility substation
  • 2N UPS – 10 minute runtime at full load
  • 2N generator plant – up to 20mW
  • 7-day onsite fuel supply – 60,000 gallon capacity
  • 2N chiller plants
  • Temperature, humidity and water alarms monitored 24×7
  • 100% uptime SLA
  • 100% concurrently maintainable
  • Overhead power distribution
  • 10kVA per rack base power provisioning

Security Programs

  • FISMA (NIST 800-53 Standards)
  • HIPAA Compliant (NIST 800-53 Standards)
  • FedRAMP Authorized for IaaS
  • Uptime Institute Tier III
  • PCI DSS
  • AICPA SOC2